SCION Liners

SCION Liners

Our carefully crafted GC liners are designed to meet the demanding requirements of various applications, providing a precise and consistent environment for sample introduction. Whether you are conducting analyses in environmental monitoring, food safety, pharmaceuticals, or any other industry reliant on accurate chemical analysis, our gas chromatography liners are engineered to elevate your chromatographic performance.

Explore our range of gas chromatography liners, each crafted with meticulous attention to detail and quality, to ensure that your analytical processes meet the highest standards. Elevate your chromatography experience with our reliable and efficient gas chromatography liner solutions.

Description

For more detailed information on our GC liners, read our Gas Chromatography Liner Guide.

Gas chromatography liners are integral components in the chromatographic process, playing a pivotal role in optimizing sample injection and vaporization within the chromatograph. These small yet crucial components ensure the accuracy and reliability of your gas chromatography analyses.

GC liners serve as a protective barrier between the sample injection system and the chromatographic column, facilitating the seamless transition of volatile compounds from the sample matrix to the analytical column. They help prevent sample contamination, enhance vaporization efficiency, and contribute to the overall reproducibility of results.

Split/Splitless injector (1177 S/SL)

  • SCION qualified inserts use highest quality glass/quartz wool for minimal degradation
  • SCION qualified inserts are deactivation treated to minimize activity
  • SCION qualified specific geometries for applications
P/N Description ID (mm) App.
41312100 LINER 1177 78.5 L x 6.3 OD x 4MM ID S/SL STRAIGHT QWOOL PK/5 4 S/SL
41312101 LINER 1177 78.5 L x 6.3 OD x 4MM ID S/SL FOCUS PK/5 4 S/SL
41312102 LINER 1177 78.5 L x 6.3 OD x 4MM ID S/SL TAPER FOCUS PK/5 4 S/SL
41312103 LINER 1177 78.5 L x 6.1 OD x 2MM ID S/SL STRAIGHT PK/5 2 S/SL
41312104 LINER 1177 78.5 L x 6.3 OD x 2MM ID S/SL FOCUS PK/5 2 S/SL
41312105 LINER 1177 78.5 L x 6.3 OD x 4MM ID S/SL STRAIGHT PK/5 4 S/SL
41312106 LINER 1177 78.5 L x 6.3 OD x 4MM ID S/SL RECESSED GOOSENECK QUARTZ WOOL PK/5 4 S/SL
41312107 LINER 1177 78.5 L x 6.3 OD x 2MM ID S/SL RECESSED GOOSENECK PK/5 2 S/SL
41312108 LINER 1177 78.5 L x 6.3 OD x 1.2MM ID S/SL STRAIGHT PK/5 1.2 Split, SPME
41312109 LINER 1177 78.5 L x 6.3 OD x 4MM ID S/SL TAPER PK/5 4 S/SL
41312110 LINER 1177 78.5 L x 6.3 OD x 4MM ID S/SL DBL TAPER PK/5 4 S/SL
41312111 LINER 1177 78.5 L x 6.3 OD x 4MM ID S/SL TAPER QUARTZ WOOL PK/5 4 S/SL
41312112 LINER 1177 78.5 L x 6.3 OD x 2.3MM ID S/SL TAPER FASTFOCUS PK/5 2.3 S/SL

Split/Splitless injector (1177 S/SL)-Advanced Liners

  • SCION Ultra inert liner inserts prevent breakdown of active compounds
  • SCION Ultra inert liner inserts realizes best peak symmetry in ‘hot injections’
P/N Description ID (mm) App.
41312113 LINER 1177 78.5 L x 6.3 OD x 0.75MM ID SPME STRAIGHT PK/5 0.75 SPME
41312114 LINER 1177 78.5 L x 6.3 OD x 4MM ID S/SL STRAIGHT QWOOL ULTRA INERT PK/5 4 S/SL
41312115 LINER 1177 78.5 L x 6.3 OD x 4MM ID S/SL TAPER FOCUS ULTRA INERT PK/5 4 S/SL
41312116 LINER 1177 78.5 L x 6.3 OD x 2.3MM ID S/SL TAPER FASTFOCUS ULTRA INERT PK/5 23 S/SL
41312117 LINER 1177 78.5 L x 6.3 OD x 4MM ID S/SL TAPER QUARTZ WOOL ULTRA INERT PK/5 4 S/SL

Split / Splitless injector (1177 S/SL) – O-ring inlet Port seals

  • SCION Injector O-rings provide best leak tight seal, avoid air leaks
  • Graphite or Viton available; Graphite allows higher temperature for inlet (max 450°C)
P/N Description
41312118 INJECTOR SEAL O-RING 1177 6.5MM ID VITON PK/10
41312119 INJECTOR SEAL O-RING 1177 6.5MM ID GRAPHITE PK/10

PTV Inlet (1078/1079 PTV), On Column Inlet (SPI/1093)

  • SCION qualified inserts use highest quality glass/quartz wool for minimal degradation
  • SCION qualified inserts are deactivation treated to minimize activity
  • SCION qualified specific geometries for applications (i.e. on-column, pseudo on-column or SPME)
P/N Description Description (mm) App
41312120 LINER 1093/SPI 54 L x 4.6 OD x 0.5MM ID COC CONNECTITE R 0.25 PK/5 0.5 On Column
41312121 LINER 1093/SPI 54 L x 4.6 OD x 0.5MM ID COC CONNECTITE R 0.25 PK/5 0.5 On Column
41312122 LINER 1093/SPI 54 L x 4.6 OD x 0.8MM ID COC CONNECTITE R 0.50 PK/5 0.8 On Column
41312123 LINER 1078/1079 54 L x 5 OD x 0.5MM ID S/SL STRAIGHT PK/5 0.5 S/SL / PTV
41312124 LINER 1078/1079 54 L x 5 OD x 3.4MM ID S/SL DOUBLE TAPER FOCUS PK/5 3.4 S/SL / PTV
41312125 LINER 1078/1079 54 L x 5 OD x 3.4MM ID S/SL FOCUS PK/5 3.4 S/SL / PTV
41312126 LINER 1078/1079 54 L x 5 OD x 3.4MM ID S/SL TAPER PK/5 3.4 S/SL / PTV
41312127 LINER 1078/1079 54 L x 5 OD x 2MM ID S/SL TAPER PK/5 2 S/SL / PTV
41312128 LINER 1078/1079 54 L x 5 OD x 0.8MM ID SPME STRAIGHT PK/5 0.8 SPME

PTV Inlet (1078/1079 PTV), On Column Inlet (SPI/1093) – Ferrules

  • Scion qualified ferrules for PTV Injectors
  • Perfect seal on inserts using liner jig, for best precision results
P/N Description
41312146 GRAPHITE SEALING FERRULE FOR 1078 & 1079 INJECTORS PK/10

Packed Wide Bore – On Column / Flash Inlet (1041/1061)

  • SCION qualified inserts use highest quality glass/quartz wool for minimal degradation
  • SCION qualified inserts are deactivation treated to minimize activity
  • SCION qualified specific geometries for applications (i.e. on-column, pseudo on-column or SPME)
P/N Description
392611943 Flash Vaporization Glass Insert for Megabore (pk of 5)
392611944 Flash Vaporization Glass Insert for Packed Col. (pk of 5)
392543101 Insert, PWOC Injector. Allows installation of 0.53 µm columns
392558891 Packed Colum Adapter Kit for On Column, 1/8″ SS Column
392558301 Flash Vaporization Column Guide for 3800