{"id":41047,"date":"2021-05-18T11:01:30","date_gmt":"2021-05-18T10:01:30","guid":{"rendered":"https:\/\/scioninstruments.com\/?page_id=41047"},"modified":"2024-01-23T15:53:10","modified_gmt":"2024-01-23T15:53:10","slug":"analysis-of-dehp-in-drinking-water-by-hplc-dad","status":"publish","type":"page","link":"https:\/\/scioninstruments.com\/us\/analysis-of-dehp-in-drinking-water-by-hplc-dad\/","title":{"rendered":"Analysis of DEHP in Drinking Water by HPLC-DAD"},"content":{"rendered":"<h2>Introduction<\/h2>\n<p>DEHP, bis-(2-ethylhexyl)phthalate, is one of the most prominent phthalate contaminants in drinking water. DEHP is also used as a plasticiser during plastic manufacturing. When ingested, it is a cancer-causing hazard and presents a high risk of liver function disorders. For this reason DEHP is a banned substance during food production, under the Restriction of Hazardous Substances (RoHS) Directive by the EU[1], and levels must be monitored. Although a banned substance, commercial sport drink manufactures have been known to substitute palm oil, a common emulsifier, for the more cost effective DEHP.<\/p>\n<p>SCION Instruments developed a method for the identification of DEHP using HPLC and a Diode Array Detector (DAD).<\/p>\n<h2>Experimental<\/h2>\n<p>A SCION LC 6000 with DAD was used with a C18 reverse phase column for the detection of DEHP in mineral water and sports drink samples. A DEHP analytical standard was prepared at a concentration range of 0.1mg\/L to 100mg\/L. Standard addition was also performed on two negative water and sports drink samples to demonstrate the capability of the instrument. Samples were spiked with 1ppm and 10ppm of DEHP prior to analysis.<\/p>\n<p>Table 1 details the analytical conditions of the HPLC-DAD system.<\/p>\n<p><strong>Table 1<\/strong>. Analytical conditions of HPLC-DAD<\/p>\n<table style=\"border-collapse: collapse; width: 41.6969%; height: 175px;\">\n<tbody>\n<tr style=\"height: 24px;\">\n<td style=\"width: 50%; height: 24px;\"><strong>Conditions<\/strong><\/td>\n<td style=\"width: 50%; height: 24px;\"><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 50%; height: 24px;\"><strong>Column\u00a0<\/strong><\/td>\n<td style=\"width: 50%; height: 24px;\">C18 5\u00b5m x 4.6mm ID x 150mm<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 50%; height: 24px;\"><strong>Column Temp<\/strong><\/td>\n<td style=\"width: 50%; height: 24px;\">30\u00b0C<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 50%; height: 24px;\"><strong>Mobile Phase<\/strong><\/td>\n<td style=\"width: 50%; height: 24px;\">Water\/Acetonitrile (2\/98 v\/v)<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 50%; height: 24px;\"><strong>Flow Rate<\/strong><\/td>\n<td style=\"width: 50%; height: 24px;\">1mL\/min<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 50%; height: 24px;\"><strong>Injection Vol<\/strong><\/td>\n<td style=\"width: 50%; height: 24px;\">10\u00b5L<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 50%; height: 24px;\"><strong>DAD<\/strong><\/td>\n<td style=\"width: 50%; height: 24px;\">224nm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Results<\/h2>\n<p>The chromatogram of a 10mg\/L DEHP standard can be observed in Figure 1 whilst Figure 2 shows the calibration curve of DEHP, over a range of 0.1mg\/L to 100mg\/L.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" loading=\"lazy\" class=\"alignnone wp-image-41054\" src=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2021\/05\/Fig-1-300x220.png\" alt=\"\" width=\"501\" height=\"367\" srcset=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2021\/05\/Fig-1-300x220.png 300w, https:\/\/scioninstruments.com\/wp-content\/uploads\/2021\/05\/Fig-1.png 635w\" sizes=\"auto, (max-width: 501px) 100vw, 501px\" \/><br \/>\n<strong>Figure 1.<\/strong> Identification of DEHP at 224nm (10mg\/L)<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" loading=\"lazy\" class=\"alignnone wp-image-41060\" src=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2021\/05\/Fig-2-300x190.png\" alt=\"\" width=\"500\" height=\"317\" srcset=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2021\/05\/Fig-2-300x190.png 300w, https:\/\/scioninstruments.com\/wp-content\/uploads\/2021\/05\/Fig-2.png 653w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><br \/>\n<strong>Figure 2.<\/strong> Calibration curve of DEHP; 0.1mg\/L to 100mg\/L<\/p>\n<p>DEHP exhibits excellent linearity over a wide concentration range, as demonstrated in Figure 2. Retention time and peak are repeatability of the system was tested with six consecutive injections of a 10mg\/L standard, the values of which can be found in Table 2.<\/p>\n<p><strong>Table 2.<\/strong> Repeatability values of 10mg\/L DEHP standard (n=6)<\/p>\n<table style=\"border-collapse: collapse; width: 39.2313%; height: 235px;\">\n<tbody>\n<tr>\n<td style=\"width: 33.3333%; text-align: center;\"><strong>Run<\/strong><\/td>\n<td style=\"width: 33.3333%; text-align: center;\"><strong>RT (min)<\/strong><\/td>\n<td style=\"width: 33.3333%; text-align: center;\"><strong>Peak Area<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%; text-align: center;\">1<\/td>\n<td style=\"width: 33.3333%; text-align: center;\">7.058<\/td>\n<td style=\"width: 33.3333%; text-align: center;\">131486<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%; text-align: center;\">2<\/td>\n<td style=\"width: 33.3333%; text-align: center;\">7.057<\/td>\n<td style=\"width: 33.3333%; text-align: center;\">131742<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%; text-align: center;\">3<\/td>\n<td style=\"width: 33.3333%; text-align: center;\">7.056<\/td>\n<td style=\"width: 33.3333%; text-align: center;\">131456<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%; text-align: center;\">4<\/td>\n<td style=\"width: 33.3333%; text-align: center;\">7.057<\/td>\n<td style=\"width: 33.3333%; text-align: center;\">131769<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%; text-align: center;\">5<\/td>\n<td style=\"width: 33.3333%; text-align: center;\">7.056<\/td>\n<td style=\"width: 33.3333%; text-align: center;\">131609<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%; text-align: center;\">6<\/td>\n<td style=\"width: 33.3333%; text-align: center;\">7.057<\/td>\n<td style=\"width: 33.3333%; text-align: center;\">131743<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%; text-align: center;\">Mean<\/td>\n<td style=\"width: 33.3333%; text-align: center;\">7.057<\/td>\n<td style=\"width: 33.3333%; text-align: center;\">131634<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%; text-align: center;\">%RSD<\/td>\n<td style=\"width: 33.3333%; text-align: center;\">0.011<\/td>\n<td style=\"width: 33.3333%; text-align: center;\">0.11<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Excellent repeatability of both retention time and peak value was observed, with RSD% values at 0.011 and 0.11, respectively; highlighting the robustness of the SCION HPLC-DAD system.<br \/>\nMineral water and a sports drink were both analysed for the presence of DEPH. However, both samples were negative. Standard addition was performed on two separate samples of each sample type with an addition of 1ppm and 10ppm DEHP.<\/p>\n<p>Figures 2 and 3 show the overlay chromatograms of both samples, including the initial blank results and both DEPH additions.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" loading=\"lazy\" class=\"alignnone wp-image-41066\" src=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2021\/05\/Fig-3-300x237.png\" alt=\"\" width=\"500\" height=\"395\" srcset=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2021\/05\/Fig-3-300x237.png 300w, https:\/\/scioninstruments.com\/wp-content\/uploads\/2021\/05\/Fig-3.png 624w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><br \/>\n<strong>Figure 3.<\/strong> Chromatogram overlay of DEHP standard addition (mineral water)<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" loading=\"lazy\" class=\"alignnone wp-image-41072\" src=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2021\/05\/Fig-4-300x236.png\" alt=\"\" width=\"500\" height=\"393\" srcset=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2021\/05\/Fig-4-300x236.png 300w, https:\/\/scioninstruments.com\/wp-content\/uploads\/2021\/05\/Fig-4.png 632w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><br \/>\n<strong>Figure 4.<\/strong> Chromatogram overlay of DEHP standard addition (sports drink)<\/p>\n<p>The above figures demonstrate the excellent sensitivity of the HPLC-DAD system even at low concentrations such as 1ppm.<\/p>\n<h2>Conclusion<\/h2>\n<p>SCION Instruments offers the ideal solution for the identification of DEHP, a restricted contamination compound by HPLC-DAD. Excellent separation, linearity over a wide concentration range and system repeatability was observed for DEHP using a C18 column at 280nm wavelength.<\/p>\n<h2>References<\/h2>\n<p>[1] European Commission (2011). Directive 2011\/65\/EU of the European Parliament and of the Council as Regards the List of Restricted Substances. European Parliament.<\/p>\n<h2>Download Application Note<\/h2>\n<p>Download complete Application Note: <a href=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2024\/01\/AN0064-Analysis-of-DEHP-in-Drinking-Water.pdf\" target=\"_blank\" rel=\"noopener\">Analysis of DEHP in Drinking Water by HPLC-DAD<\/a><\/p>\n<h2><strong>Keep in Touch<\/strong><\/h2>\n<p>If you wish to speak to a member of our team about more information, please don\u2019t hesitate to contact us. Or if you wish to keep up to date with SCION Instruments latest research and articles, why not join us on social media and sign up to our newsletters today?<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Introduction DEHP, bis-(2-ethylhexyl)phthalate, is one of the most prominent phthalate contaminants in drinking water. DEHP is also used as a plasticiser during plastic manufacturing. When ingested, it is a cancer-causing hazard and presents a high risk of liver function disorders. For this reason DEHP is a banned substance during food production, under the Restriction of [&hellip;]<\/p>\n","protected":false},"author":15,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-41047","page","type-page","status-publish","hentry"],"acf":{"rf_hero_height":"default","rf_hero_type":"default","rf_hero_vertpos":"50","rf_hero_horizpos":"50","rf_hero_title":"","rf_hero_title_hide":false,"rf_hero_textcol":"light","rf_hero_bgcol":"white","rf_hero_tint":false,"rf_sitemap_hide":false,"rf_further_reading_posts":false},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.0 (Yoast SEO v27.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Analysis of DEHP in Drinking Water by HPLC-DAD | SCION Instruments<\/title>\n<meta name=\"description\" content=\"SCION Instruments developed a method for the identification of DEHP using HPLC and a Diode Array Detector (DAD).\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/scioninstruments.com\/us\/analysis-of-dehp-in-drinking-water-by-hplc-dad\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Analysis of DEHP in Drinking Water by HPLC-DAD\" \/>\n<meta property=\"og:description\" content=\"SCION Instruments developed a method for the identification of DEHP using HPLC and a Diode Array Detector (DAD).\" \/>\n<meta property=\"og:url\" content=\"https:\/\/scioninstruments.com\/us\/analysis-of-dehp-in-drinking-water-by-hplc-dad\/\" \/>\n<meta property=\"og:site_name\" content=\"SCION Instruments\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/scioninst\/\" \/>\n<meta property=\"article:modified_time\" content=\"2024-01-23T15:53:10+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2021\/05\/Fig-1-300x220.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/scioninstruments.com\/us\/analysis-of-dehp-in-drinking-water-by-hplc-dad\/\",\"url\":\"https:\/\/scioninstruments.com\/us\/analysis-of-dehp-in-drinking-water-by-hplc-dad\/\",\"name\":\"Analysis of DEHP in Drinking Water by HPLC-DAD | SCION Instruments\",\"isPartOf\":{\"@id\":\"https:\/\/scioninstruments.com\/us\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/scioninstruments.com\/us\/analysis-of-dehp-in-drinking-water-by-hplc-dad\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/scioninstruments.com\/us\/analysis-of-dehp-in-drinking-water-by-hplc-dad\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2021\/05\/Fig-1-300x220.png\",\"datePublished\":\"2021-05-18T10:01:30+00:00\",\"dateModified\":\"2024-01-23T15:53:10+00:00\",\"description\":\"SCION Instruments developed a method for the identification of DEHP using HPLC and a Diode Array Detector (DAD).\",\"breadcrumb\":{\"@id\":\"https:\/\/scioninstruments.com\/us\/analysis-of-dehp-in-drinking-water-by-hplc-dad\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/scioninstruments.com\/us\/analysis-of-dehp-in-drinking-water-by-hplc-dad\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/scioninstruments.com\/us\/analysis-of-dehp-in-drinking-water-by-hplc-dad\/#primaryimage\",\"url\":\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2021\/05\/Fig-1-300x220.png\",\"contentUrl\":\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2021\/05\/Fig-1-300x220.png\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/scioninstruments.com\/us\/analysis-of-dehp-in-drinking-water-by-hplc-dad\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/scioninstruments.com\/us\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Analysis of DEHP in Drinking Water by HPLC-DAD\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/scioninstruments.com\/us\/#website\",\"url\":\"https:\/\/scioninstruments.com\/us\/\",\"name\":\"SCION Instruments\",\"description\":\"Gas and Liquid Chromatography Solutions\",\"publisher\":{\"@id\":\"https:\/\/scioninstruments.com\/us\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/scioninstruments.com\/us\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/scioninstruments.com\/us\/#organization\",\"name\":\"SCION Instruments\",\"url\":\"https:\/\/scioninstruments.com\/us\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/scioninstruments.com\/us\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2025\/02\/SCION-logo-TC-Strap-CMYK-transparent-background-1.png\",\"contentUrl\":\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2025\/02\/SCION-logo-TC-Strap-CMYK-transparent-background-1.png\",\"width\":3000,\"height\":1500,\"caption\":\"SCION Instruments\"},\"image\":{\"@id\":\"https:\/\/scioninstruments.com\/us\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/scioninst\/\",\"https:\/\/www.linkedin.com\/company\/scion-instruments\/\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Analysis of DEHP in Drinking Water by HPLC-DAD | SCION Instruments","description":"SCION Instruments developed a method for the identification of DEHP using HPLC and a Diode Array Detector (DAD).","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/scioninstruments.com\/us\/analysis-of-dehp-in-drinking-water-by-hplc-dad\/","og_locale":"en_US","og_type":"article","og_title":"Analysis of DEHP in Drinking Water by HPLC-DAD","og_description":"SCION Instruments developed a method for the identification of DEHP using HPLC and a Diode Array Detector (DAD).","og_url":"https:\/\/scioninstruments.com\/us\/analysis-of-dehp-in-drinking-water-by-hplc-dad\/","og_site_name":"SCION Instruments","article_publisher":"https:\/\/www.facebook.com\/scioninst\/","article_modified_time":"2024-01-23T15:53:10+00:00","og_image":[{"url":"https:\/\/scioninstruments.com\/wp-content\/uploads\/2021\/05\/Fig-1-300x220.png","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/scioninstruments.com\/us\/analysis-of-dehp-in-drinking-water-by-hplc-dad\/","url":"https:\/\/scioninstruments.com\/us\/analysis-of-dehp-in-drinking-water-by-hplc-dad\/","name":"Analysis of DEHP in Drinking Water by HPLC-DAD | SCION Instruments","isPartOf":{"@id":"https:\/\/scioninstruments.com\/us\/#website"},"primaryImageOfPage":{"@id":"https:\/\/scioninstruments.com\/us\/analysis-of-dehp-in-drinking-water-by-hplc-dad\/#primaryimage"},"image":{"@id":"https:\/\/scioninstruments.com\/us\/analysis-of-dehp-in-drinking-water-by-hplc-dad\/#primaryimage"},"thumbnailUrl":"https:\/\/scioninstruments.com\/wp-content\/uploads\/2021\/05\/Fig-1-300x220.png","datePublished":"2021-05-18T10:01:30+00:00","dateModified":"2024-01-23T15:53:10+00:00","description":"SCION Instruments developed a method for the identification of DEHP using HPLC and a Diode Array Detector (DAD).","breadcrumb":{"@id":"https:\/\/scioninstruments.com\/us\/analysis-of-dehp-in-drinking-water-by-hplc-dad\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/scioninstruments.com\/us\/analysis-of-dehp-in-drinking-water-by-hplc-dad\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/scioninstruments.com\/us\/analysis-of-dehp-in-drinking-water-by-hplc-dad\/#primaryimage","url":"https:\/\/scioninstruments.com\/wp-content\/uploads\/2021\/05\/Fig-1-300x220.png","contentUrl":"https:\/\/scioninstruments.com\/wp-content\/uploads\/2021\/05\/Fig-1-300x220.png"},{"@type":"BreadcrumbList","@id":"https:\/\/scioninstruments.com\/us\/analysis-of-dehp-in-drinking-water-by-hplc-dad\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/scioninstruments.com\/us\/"},{"@type":"ListItem","position":2,"name":"Analysis of DEHP in Drinking Water by HPLC-DAD"}]},{"@type":"WebSite","@id":"https:\/\/scioninstruments.com\/us\/#website","url":"https:\/\/scioninstruments.com\/us\/","name":"SCION Instruments","description":"Gas and Liquid Chromatography Solutions","publisher":{"@id":"https:\/\/scioninstruments.com\/us\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/scioninstruments.com\/us\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/scioninstruments.com\/us\/#organization","name":"SCION Instruments","url":"https:\/\/scioninstruments.com\/us\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/scioninstruments.com\/us\/#\/schema\/logo\/image\/","url":"https:\/\/scioninstruments.com\/wp-content\/uploads\/2025\/02\/SCION-logo-TC-Strap-CMYK-transparent-background-1.png","contentUrl":"https:\/\/scioninstruments.com\/wp-content\/uploads\/2025\/02\/SCION-logo-TC-Strap-CMYK-transparent-background-1.png","width":3000,"height":1500,"caption":"SCION Instruments"},"image":{"@id":"https:\/\/scioninstruments.com\/us\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/scioninst\/","https:\/\/www.linkedin.com\/company\/scion-instruments\/"]}]}},"_links":{"self":[{"href":"https:\/\/scioninstruments.com\/us\/wp-json\/wp\/v2\/pages\/41047","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scioninstruments.com\/us\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/scioninstruments.com\/us\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/scioninstruments.com\/us\/wp-json\/wp\/v2\/users\/15"}],"replies":[{"embeddable":true,"href":"https:\/\/scioninstruments.com\/us\/wp-json\/wp\/v2\/comments?post=41047"}],"version-history":[{"count":0,"href":"https:\/\/scioninstruments.com\/us\/wp-json\/wp\/v2\/pages\/41047\/revisions"}],"wp:attachment":[{"href":"https:\/\/scioninstruments.com\/us\/wp-json\/wp\/v2\/media?parent=41047"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}