{"id":35426,"date":"2020-12-11T12:06:19","date_gmt":"2020-12-11T12:06:19","guid":{"rendered":"https:\/\/scioninstruments.com\/fast-analysis-of-boiling-point-distributions-in-petroleum-fractions-using-simulated-distillation-astm-d2887-b\/"},"modified":"2023-10-23T13:29:42","modified_gmt":"2023-10-23T12:29:42","slug":"fast-analysis-of-boiling-point-distributions-in-petroleum-fractions-using-simulated-distillation-astm-d2887-b","status":"publish","type":"page","link":"https:\/\/scioninstruments.com\/us\/fast-analysis-of-boiling-point-distributions-in-petroleum-fractions-using-simulated-distillation-astm-d2887-b\/","title":{"rendered":"Fast analysis of Boiling Point Distributions in Petroleum Fractions using Simulated Distillation (ASTM D2887-B)"},"content":{"rendered":"<h2>Introduction<img loading=\"lazy\" decoding=\"async\" loading=\"lazy\" class=\"alignright\" src=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/06\/Jet-Fuel-300x300.jpg\" alt=\"Jet Fuel\" width=\"250\" height=\"250\" \/><\/h2>\n<p>In many regions ASTM D 2887 may be used for determining the boiling point distribution of petroleum products, feedstocks and fractions that have a final boiling point of 538\u00b0C or lower. This provides insight into composition and allows for the determination of intrinsic product value.<\/p>\n<p>While Physical Distillation is still considered the reference method for distillation, and therefore mandatory in many countries for qualifying fuels, Simulated Distillation (SIMDIST) by gas chromatography offers some significant advantages over the physical procedure, making this technique quite useful.<\/p>\n<p>Analysis by GC typically has the better precision, higher throughput, less hands-on time and lower cost per sample. Also, SIMDIST requires considerably less sample to be run and can generally be considered the safer of the two techniques.<\/p>\n<p>In addition to the standard analytical method (procedure A), a second procedure is described in ASTM D2887 (procedure B), which is the accelerated (or fast) method, which is the subject of this application note.<\/p>\n<p>This application note demonstrates a solution for D 2887 procedure B for analyzing Petroleum products covering a boiling point range from 36\u00b0C to 545\u00b0C.This procedure is also suited for biodiesels.<\/p>\n<p>For gasolines, method D 7096 should be used.<\/p>\n<ul>\n<li>Boiling range distributions obtained by this test method are essentially equivalent to those obtained by true boiling point (TBP) distillation (see method ASTM D2892).<\/li>\n<li>The results are not equivalent to results from low efficiency distillations such as those obtained with methods ASTM D86 or D1160.<\/li>\n<\/ul>\n<h2>Experimental<\/h2>\n<p>The SCION SIMDIST analyzer comprises of either a 456-GC or a 436-GC, configured with a cool on column (COC) injector, a 5m x 0,53mm x 2.65\u00b5m SIMDIST column, and a Flame Ionization Detector (FID).<\/p>\n<p>Analytical conditions for the SIMDIST analysis can be found in table 1.<\/p>\n<p>A qualitative mixture of normal paraffins covering the range from C5 up to C44 (1% wt. each in CS2) was used to determine the relationship of boiling point (BP) versus retention times (RT).<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" loading=\"lazy\" class=\"alignnone wp-image-33122\" src=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/boiling-point-distributions-1-392x460-1.jpg\" alt=\"\" width=\"350\" height=\"411\" srcset=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/boiling-point-distributions-1-392x460-1.jpg 392w, https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/boiling-point-distributions-1-392x460-1-256x300.jpg 256w\" sizes=\"auto, (max-width: 350px) 100vw, 350px\" \/><br \/>\n<strong>Table 1.<\/strong> Analytical conditions<\/p>\n<h2>Results<\/h2>\n<p>Figures 1 and 2 show a chromatogram of the normal paraffins calibration standard and the resulting RT vs BP calibration curve as used for this analysis.<\/p>\n<p>In order to check that the requirements of ASTM D2887 are met using this configuration, Reference Gasoil No. 2 was analysed 11 times, consecutively.<\/p>\n<p>Figure 3 shows a chromatogram of this Reference Gasoil, with table 2 showing the analytical results set out against the reference values and maximum allowable deviations.<\/p>\n<p>All results obtained via this method, using this configuration fall within the allowed limits for ASTM D2887.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-33128\" src=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/boiling-point-distributions-2-350x300-1.jpg\" alt=\"\" width=\"350\" height=\"300\" srcset=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/boiling-point-distributions-2-350x300-1.jpg 350w, https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/boiling-point-distributions-2-350x300-1-300x257.jpg 300w\" sizes=\"auto, (max-width: 350px) 100vw, 350px\" \/><br \/>\n<strong>Table 2.<\/strong> Results, reference values and allowable difference<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" loading=\"lazy\" class=\"alignnone wp-image-33134\" src=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/boiling-point-distributions-3-247x460-1.jpg\" alt=\"\" width=\"240\" height=\"447\" srcset=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/boiling-point-distributions-3-247x460-1.jpg 247w, https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/boiling-point-distributions-3-247x460-1-161x300.jpg 161w\" sizes=\"auto, (max-width: 240px) 100vw, 240px\" \/><br \/>\n<strong>Table 3.<\/strong> Obtained Precision<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" loading=\"lazy\" class=\"alignnone wp-image-33140\" src=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/boiling-point-distributions-4-560x353-1.jpg\" alt=\"\" width=\"451\" height=\"284\" srcset=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/boiling-point-distributions-4-560x353-1.jpg 560w, https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/boiling-point-distributions-4-560x353-1-300x189.jpg 300w\" sizes=\"auto, (max-width: 451px) 100vw, 451px\" \/><br \/>\n<strong>Figure 1.<\/strong> D2887 Cal. STD (C5-C44)<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" loading=\"lazy\" class=\"alignnone wp-image-33146\" src=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/boiling-point-distributions-5-560x349-1.jpg\" alt=\"\" width=\"451\" height=\"281\" srcset=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/boiling-point-distributions-5-560x349-1.jpg 560w, https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/boiling-point-distributions-5-560x349-1-300x187.jpg 300w\" sizes=\"auto, (max-width: 451px) 100vw, 451px\" \/><br \/>\n<strong>Figure 2.<\/strong> D2887 Cal. STD (C5-C44)<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" loading=\"lazy\" class=\"alignnone wp-image-33152\" src=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/boiling-point-distributions-6-560x354-1.jpg\" alt=\"\" width=\"451\" height=\"285\" srcset=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/boiling-point-distributions-6-560x354-1.jpg 560w, https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/boiling-point-distributions-6-560x354-1-300x190.jpg 300w\" sizes=\"auto, (max-width: 451px) 100vw, 451px\" \/><br \/>\n<strong>Figure 3.<\/strong> Reference Gasoil No. 2<\/p>\n<h2>Conclusion<\/h2>\n<p>The obtained results demonstrate that this Scion Instruments SIMDIST configuration for ASTM D2887 procedure B passes the criteria set forth in the referenced method, with an analysis time that is 4x faster than procedure A.<\/p>\n<p>Please note that:<\/p>\n<ul>\n<li>The gas chromatographic simulation of this determination can be used to replace conventional distillation methods for control of refining operations.<\/li>\n<\/ul>\n<h2>Download Application Note<\/h2>\n<p>Download the complete Application Note: <a href=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/0008_ASTMD2887_SimDist.1.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Fast analysis of Boiling Point Distributions in Petroleum Fractions using Simulated Distillation (ASTM D2887-B)<\/a><\/p>\n<h2>SCION Gas Chromatography Analyser<\/h2>\n<p>Providing excellent solutions for Environmental, Oil and Gas and Chemical industries, find out more about <a href=\"https:\/\/scioninstruments.com\/types\/scion-gc-analysers\/\">Scion GC Analysers<\/a>.<\/p>\n<p>Alternatively if you would like to speak to a member of our team for more information, please don\u2019t hesitate to\u00a0<a href=\"\/?page_id=17\">get in touch.<\/a>\u00a0We look forward to being of assistance.<\/p>\n<p>To stay in the loop regarding future research and articles from SCION Instruments, please take a minute to join us on social media and sign up to our eNewsletter.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Introduction In many regions ASTM D 2887 may be used for determining the boiling point distribution of petroleum products, feedstocks and fractions that have a final boiling point of 538\u00b0C or lower. This provides insight into composition and allows for the determination of intrinsic product value. While Physical Distillation is still considered the reference method [&hellip;]<\/p>\n","protected":false},"author":15,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-35426","page","type-page","status-publish","hentry"],"acf":{"rf_hero_height":"default","rf_hero_type":"default","rf_hero_vertpos":"50","rf_hero_horizpos":"50","rf_hero_title":"","rf_hero_textcol":"light","rf_hero_bgcol":"white","rf_hero_tint":false,"rf_hero_title_hide":false,"rf_further_reading_posts":false},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.0 (Yoast SEO v27.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Fast analysis of Boiling Point Distributions in Petroleum Fractions | Simulated Distillation<\/title>\n<meta name=\"description\" content=\"In many regions ASTM D 2887 may be used for determining the boiling point distribution of petroleum products, feedstocks and fractions that have a final boiling point of 538\u00b0C or lower.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/scioninstruments.com\/us\/fast-analysis-of-boiling-point-distributions-in-petroleum-fractions-using-simulated-distillation-astm-d2887-b\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Fast analysis of Boiling Point Distributions in Petroleum Fractions using Simulated Distillation (ASTM D2887-B)\" \/>\n<meta property=\"og:description\" content=\"In many regions ASTM D 2887 may be used for determining the boiling point distribution of petroleum products, feedstocks and fractions that have a final boiling point of 538\u00b0C or lower.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/scioninstruments.com\/fast-analysis-of-boiling-point-distributions-in-petroleum-fractions-using-simulated-distillation-astm-d2887-b\/\" \/>\n<meta property=\"og:site_name\" content=\"SCION Instruments\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/scioninst\/\" \/>\n<meta property=\"article:modified_time\" content=\"2023-10-23T12:29:42+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/06\/Jet-Fuel-300x300.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/scioninstruments.com\/us\/fast-analysis-of-boiling-point-distributions-in-petroleum-fractions-using-simulated-distillation-astm-d2887-b\/\",\"url\":\"https:\/\/scioninstruments.com\/fast-analysis-of-boiling-point-distributions-in-petroleum-fractions-using-simulated-distillation-astm-d2887-b\/\",\"name\":\"Fast analysis of Boiling Point Distributions in Petroleum Fractions | Simulated Distillation\",\"isPartOf\":{\"@id\":\"https:\/\/scioninstruments.com\/us\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/scioninstruments.com\/fast-analysis-of-boiling-point-distributions-in-petroleum-fractions-using-simulated-distillation-astm-d2887-b\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/scioninstruments.com\/fast-analysis-of-boiling-point-distributions-in-petroleum-fractions-using-simulated-distillation-astm-d2887-b\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/06\/Jet-Fuel-300x300.jpg\",\"datePublished\":\"2020-12-11T12:06:19+00:00\",\"dateModified\":\"2023-10-23T12:29:42+00:00\",\"description\":\"In many regions ASTM D 2887 may be used for determining the boiling point distribution of petroleum products, feedstocks and fractions that have a final boiling point of 538\u00b0C or lower.\",\"breadcrumb\":{\"@id\":\"https:\/\/scioninstruments.com\/fast-analysis-of-boiling-point-distributions-in-petroleum-fractions-using-simulated-distillation-astm-d2887-b\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/scioninstruments.com\/fast-analysis-of-boiling-point-distributions-in-petroleum-fractions-using-simulated-distillation-astm-d2887-b\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/scioninstruments.com\/fast-analysis-of-boiling-point-distributions-in-petroleum-fractions-using-simulated-distillation-astm-d2887-b\/#primaryimage\",\"url\":\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/06\/Jet-Fuel-300x300.jpg\",\"contentUrl\":\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/06\/Jet-Fuel-300x300.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/scioninstruments.com\/fast-analysis-of-boiling-point-distributions-in-petroleum-fractions-using-simulated-distillation-astm-d2887-b\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/scioninstruments.com\/us\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Fast analysis of Boiling Point Distributions in Petroleum Fractions using Simulated Distillation (ASTM D2887-B)\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/scioninstruments.com\/us\/#website\",\"url\":\"https:\/\/scioninstruments.com\/us\/\",\"name\":\"SCION Instruments\",\"description\":\"Gas and Liquid Chromatography Solutions\",\"publisher\":{\"@id\":\"https:\/\/scioninstruments.com\/us\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/scioninstruments.com\/us\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/scioninstruments.com\/us\/#organization\",\"name\":\"SCION Instruments\",\"url\":\"https:\/\/scioninstruments.com\/us\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/scioninstruments.com\/us\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2025\/02\/SCION-logo-TC-Strap-CMYK-transparent-background-1.png\",\"contentUrl\":\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2025\/02\/SCION-logo-TC-Strap-CMYK-transparent-background-1.png\",\"width\":3000,\"height\":1500,\"caption\":\"SCION Instruments\"},\"image\":{\"@id\":\"https:\/\/scioninstruments.com\/us\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/scioninst\/\",\"https:\/\/www.linkedin.com\/company\/scion-instruments\/\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Fast analysis of Boiling Point Distributions in Petroleum Fractions | Simulated Distillation","description":"In many regions ASTM D 2887 may be used for determining the boiling point distribution of petroleum products, feedstocks and fractions that have a final boiling point of 538\u00b0C or lower.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/scioninstruments.com\/us\/fast-analysis-of-boiling-point-distributions-in-petroleum-fractions-using-simulated-distillation-astm-d2887-b\/","og_locale":"en_US","og_type":"article","og_title":"Fast analysis of Boiling Point Distributions in Petroleum Fractions using Simulated Distillation (ASTM D2887-B)","og_description":"In many regions ASTM D 2887 may be used for determining the boiling point distribution of petroleum products, feedstocks and fractions that have a final boiling point of 538\u00b0C or lower.","og_url":"https:\/\/scioninstruments.com\/fast-analysis-of-boiling-point-distributions-in-petroleum-fractions-using-simulated-distillation-astm-d2887-b\/","og_site_name":"SCION Instruments","article_publisher":"https:\/\/www.facebook.com\/scioninst\/","article_modified_time":"2023-10-23T12:29:42+00:00","og_image":[{"url":"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/06\/Jet-Fuel-300x300.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/scioninstruments.com\/us\/fast-analysis-of-boiling-point-distributions-in-petroleum-fractions-using-simulated-distillation-astm-d2887-b\/","url":"https:\/\/scioninstruments.com\/fast-analysis-of-boiling-point-distributions-in-petroleum-fractions-using-simulated-distillation-astm-d2887-b\/","name":"Fast analysis of Boiling Point Distributions in Petroleum Fractions | Simulated Distillation","isPartOf":{"@id":"https:\/\/scioninstruments.com\/us\/#website"},"primaryImageOfPage":{"@id":"https:\/\/scioninstruments.com\/fast-analysis-of-boiling-point-distributions-in-petroleum-fractions-using-simulated-distillation-astm-d2887-b\/#primaryimage"},"image":{"@id":"https:\/\/scioninstruments.com\/fast-analysis-of-boiling-point-distributions-in-petroleum-fractions-using-simulated-distillation-astm-d2887-b\/#primaryimage"},"thumbnailUrl":"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/06\/Jet-Fuel-300x300.jpg","datePublished":"2020-12-11T12:06:19+00:00","dateModified":"2023-10-23T12:29:42+00:00","description":"In many regions ASTM D 2887 may be used for determining the boiling point distribution of petroleum products, feedstocks and fractions that have a final boiling point of 538\u00b0C or lower.","breadcrumb":{"@id":"https:\/\/scioninstruments.com\/fast-analysis-of-boiling-point-distributions-in-petroleum-fractions-using-simulated-distillation-astm-d2887-b\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/scioninstruments.com\/fast-analysis-of-boiling-point-distributions-in-petroleum-fractions-using-simulated-distillation-astm-d2887-b\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/scioninstruments.com\/fast-analysis-of-boiling-point-distributions-in-petroleum-fractions-using-simulated-distillation-astm-d2887-b\/#primaryimage","url":"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/06\/Jet-Fuel-300x300.jpg","contentUrl":"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/06\/Jet-Fuel-300x300.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/scioninstruments.com\/fast-analysis-of-boiling-point-distributions-in-petroleum-fractions-using-simulated-distillation-astm-d2887-b\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/scioninstruments.com\/us\/"},{"@type":"ListItem","position":2,"name":"Fast analysis of Boiling Point Distributions in Petroleum Fractions using Simulated Distillation (ASTM D2887-B)"}]},{"@type":"WebSite","@id":"https:\/\/scioninstruments.com\/us\/#website","url":"https:\/\/scioninstruments.com\/us\/","name":"SCION Instruments","description":"Gas and Liquid Chromatography Solutions","publisher":{"@id":"https:\/\/scioninstruments.com\/us\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/scioninstruments.com\/us\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/scioninstruments.com\/us\/#organization","name":"SCION Instruments","url":"https:\/\/scioninstruments.com\/us\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/scioninstruments.com\/us\/#\/schema\/logo\/image\/","url":"https:\/\/scioninstruments.com\/wp-content\/uploads\/2025\/02\/SCION-logo-TC-Strap-CMYK-transparent-background-1.png","contentUrl":"https:\/\/scioninstruments.com\/wp-content\/uploads\/2025\/02\/SCION-logo-TC-Strap-CMYK-transparent-background-1.png","width":3000,"height":1500,"caption":"SCION Instruments"},"image":{"@id":"https:\/\/scioninstruments.com\/us\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/scioninst\/","https:\/\/www.linkedin.com\/company\/scion-instruments\/"]}]}},"_links":{"self":[{"href":"https:\/\/scioninstruments.com\/us\/wp-json\/wp\/v2\/pages\/35426","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scioninstruments.com\/us\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/scioninstruments.com\/us\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/scioninstruments.com\/us\/wp-json\/wp\/v2\/users\/15"}],"replies":[{"embeddable":true,"href":"https:\/\/scioninstruments.com\/us\/wp-json\/wp\/v2\/comments?post=35426"}],"version-history":[{"count":0,"href":"https:\/\/scioninstruments.com\/us\/wp-json\/wp\/v2\/pages\/35426\/revisions"}],"wp:attachment":[{"href":"https:\/\/scioninstruments.com\/us\/wp-json\/wp\/v2\/media?parent=35426"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}