{"id":35401,"date":"2020-12-11T11:37:08","date_gmt":"2020-12-11T11:37:08","guid":{"rendered":"https:\/\/scioninstruments.com\/determination-of-total-fame-and-linolenic-acid-methyl-esters-in-biodiesel\/"},"modified":"2024-02-08T14:54:45","modified_gmt":"2024-02-08T14:54:45","slug":"determination-of-total-fame-and-linolenic-acid-methyl-esters-in-biodiesel","status":"publish","type":"page","link":"https:\/\/scioninstruments.com\/us\/determination-of-total-fame-and-linolenic-acid-methyl-esters-in-biodiesel\/","title":{"rendered":"Determination of Total FAME and Linolenic Acid Methyl Esters in Biodiesel"},"content":{"rendered":"<h2>Introduction<a href=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/Untitled-design-6-600x600-1.png\"><img loading=\"lazy\" decoding=\"async\" loading=\"lazy\" class=\"alignright wp-image-34086\" src=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/Untitled-design-6-600x600-1.png\" alt=\"EN 14103\" width=\"252\" height=\"252\" srcset=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/Untitled-design-6-600x600-1.png 600w, https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/Untitled-design-6-600x600-1-300x300.png 300w, https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/Untitled-design-6-600x600-1-150x150.png 150w\" sizes=\"auto, (max-width: 252px) 100vw, 252px\" \/><\/a><\/h2>\n<p>For biodiesel to be used as a motor fuel or blended with petroleum diesel, it must conform to standard specifications (ASTM D 6751 or EN-14214). There are standard GC methods in use today to determine if biodiesel conforms to the standard specifications, one of which is <strong>EN-14103<\/strong>, used to determine the ester and linoleic acid methyl ester content. Other methods include EN-14105 \/ ASTM D 6584 (free and total glycerin and mono, di and triglyceride content) and EN-14110 (residual methanol). SCION Instruments has designed GC solutions for each of these standard methods. This paper describes work conducted on the SCION Instruments 8300 gas chromatograph to analyse biodiesel (B-100) in accordance with EN-14103. EN-14103 is used to verify that the ester content of Fatty Acid Methyl Esters (FAME) is greater than 90% and that the linolenic acid content is between 1 % (m\/m) and 15 % (m\/m) consistent with EN-14214 specifications.<\/p>\n<p>This method is suitable for FAME which contains methyl esters between C14 and C24.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" loading=\"lazy\" class=\"alignnone wp-image-34080\" src=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/SCION-AN0076-Determination-of-Total-FAME-and.jpg\" alt=\"EN 14103\" width=\"451\" height=\"285\" srcset=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/SCION-AN0076-Determination-of-Total-FAME-and.jpg 747w, https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/SCION-AN0076-Determination-of-Total-FAME-and-300x190.jpg 300w\" sizes=\"auto, (max-width: 451px) 100vw, 451px\" \/><br \/>\n<span style=\"color: #1b66b1;\">Fig.1<\/span>\u00a0Biodiesel Chromatogram<\/p>\n<table style=\"height: 625px;\" width=\"280\">\n<tbody>\n<tr>\n<td width=\"113\"><strong>\u00a0<\/strong><\/td>\n<td width=\"208\"><strong>\u00a0<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"113\"><strong>C16:0<\/strong><\/td>\n<td width=\"208\">Palmitic Acid<\/td>\n<\/tr>\n<tr>\n<td width=\"113\"><strong>C16:1<\/strong><\/td>\n<td width=\"208\">Palmitoleic acid<\/td>\n<\/tr>\n<tr>\n<td width=\"113\"><strong>C17:0<\/strong><\/td>\n<td width=\"208\">Heptadecanoic acid<\/p>\n<p>(internal standard)<\/td>\n<\/tr>\n<tr>\n<td width=\"113\"><strong>C18:0<\/strong><\/td>\n<td width=\"208\">Stearic acid<\/td>\n<\/tr>\n<tr>\n<td width=\"113\"><strong>C18:1<\/strong><\/td>\n<td width=\"208\">Oleic acid<\/td>\n<\/tr>\n<tr>\n<td width=\"113\"><strong>C18:2<\/strong><\/td>\n<td width=\"208\">Linoleic acid<\/td>\n<\/tr>\n<tr>\n<td width=\"113\"><strong>C18:3<\/strong><\/td>\n<td width=\"208\">Linolenic acid<\/td>\n<\/tr>\n<tr>\n<td width=\"113\"><strong>C20:0<\/strong><\/td>\n<td width=\"208\">Arachidic acid<\/td>\n<\/tr>\n<tr>\n<td width=\"113\"><strong>C20:1<\/strong><\/td>\n<td width=\"208\">Gadoleic acid<\/td>\n<\/tr>\n<tr>\n<td width=\"113\"><strong>C22:0<\/strong><\/td>\n<td width=\"208\">Behenic acid<\/td>\n<\/tr>\n<tr>\n<td width=\"113\"><strong>C22:1<\/strong><\/td>\n<td width=\"208\">Erucic acid<\/td>\n<\/tr>\n<tr>\n<td width=\"113\"><strong>C24:0<\/strong><\/td>\n<td width=\"208\">Lignoceric acid<\/td>\n<\/tr>\n<tr>\n<td width=\"113\"><strong>C24:1<\/strong><\/td>\n<td width=\"208\">Nervonic acid<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Table 1. Identification<\/strong><\/p>\n<h2>Experimental<\/h2>\n<p>The SCION Biodiesel analyser for EN 14103 is based on our 8300 GC platform, a split\/splitless injector, a SCION WAXMS analytical column and an FID Detector. Analytical conditions for the EN 14103 analysis can be found in table 1. When the conditions outlined below are applied, a chromatogram is obtained, as in Figure 1.<\/p>\n<table style=\"height: 325px;\" width=\"382\">\n<tbody>\n<tr>\n<td width=\"301\"><strong>Injector<\/strong><\/td>\n<td width=\"301\"><strong>Split\/Splitless @ 250\u00b0C<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"301\"><strong>Column <\/strong><\/td>\n<td width=\"301\">30m x 0. 25 mm x 0. 25 \u03bcm<\/p>\n<p>SCION WAXMS (SC32423)<\/td>\n<\/tr>\n<tr>\n<td width=\"301\"><strong>Oven Program<\/strong><\/td>\n<td width=\"301\">210\u00baC Isothermal<\/td>\n<\/tr>\n<tr>\n<td width=\"301\"><strong>Carrier<\/strong><\/td>\n<td width=\"301\">Helium @ 12 psi (83 kPa)<\/td>\n<\/tr>\n<tr>\n<td width=\"301\"><strong>Detector<\/strong><\/td>\n<td width=\"301\">FID @ 250\u00baC<\/td>\n<\/tr>\n<tr>\n<td width=\"301\"><strong>Inj. Volume<\/strong><\/td>\n<td width=\"301\">1\u00b5l<\/td>\n<\/tr>\n<tr>\n<td width=\"301\"><strong>Software<\/strong><\/td>\n<td width=\"301\">Compass CDS<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"color: #1b66b1;\">Table 1.<\/span> Analytical Conditions<\/p>\n<h2>Sample Preparation<\/h2>\n<p>Accurately weigh approximately 250 mg of sample in a 10 mL vial, then add 5 mL of methyl heptadecanoate solution (10 mg \/ mL) using a<br \/>\npipette.<\/p>\n<h2>Calculations<\/h2>\n<p>The ester content (C), expressed as a mass fraction in percent, is calculated using the following formula:<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" loading=\"lazy\" class=\"alignnone wp-image-34098\" src=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/Formula-Image-350x64-1.jpg\" alt=\"\" width=\"345\" height=\"63\" srcset=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/Formula-Image-350x64-1.jpg 350w, https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/Formula-Image-350x64-1-300x55.jpg 300w\" sizes=\"auto, (max-width: 345px) 100vw, 345px\" \/><\/p>\n<p>Where:<\/p>\n<p><strong>\u03a3A<\/strong> \u2192 total peak area from C14:0 to C24:1<br \/>\n<strong>AEI<\/strong> \u2192 peak area of C17:0<br \/>\n<strong>CEI<\/strong> \u2192 is the concentration, in mg\/ml, of the C17:0 solution<br \/>\n<strong>VEI<\/strong> \u2192 volume, in ml, of the C17:0 solution<br \/>\n<strong>m<\/strong> \u2192\u00a0mass, in mg, of the sample<br \/>\nThe linolenic acid methyl ester content (L), expressed as a mass fraction in percent, is calculated using the following formula:<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" loading=\"lazy\" class=\"alignnone wp-image-34092\" src=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/Formula-Image-2-350x86-1.jpg\" alt=\"\" width=\"342\" height=\"84\" srcset=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/Formula-Image-2-350x86-1.jpg 350w, https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/Formula-Image-2-350x86-1-300x74.jpg 300w\" sizes=\"auto, (max-width: 342px) 100vw, 342px\" \/><br \/>\nWhere:<\/p>\n<p><strong>\u03a3A<\/strong> \u2192 total peak area from C14:0 to C24:1<br \/>\n<strong>AEI<\/strong> \u2192 peak area of C17:0<br \/>\n<strong>AL<\/strong> \u2192 peak area of C18:3<\/p>\n<h2>Results<\/h2>\n<p>The results of the biodiesel assay are stated in Table 3. The biodiesel sample tested was shown to be in accordance with the requirements stated in EN 14214 (the method requirements: FAME content &gt; 96.5 % (m\/m) and linolenic acid content &lt; 12 % (m\/m)).<\/p>\n<p>In order to verify the integrity of the system, repeatability was determined (n=15). See Table 4 and Figure 2. A relative standard deviation of 0.21 % was achieved. Figure 2 shows the mass % results of the subsequent injections and the absolute difference obtained compared to specification limits.<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"106\"><strong>\u00a0<\/strong><\/td>\n<td width=\"112\"><strong>Area (<\/strong><strong>\u00b5V.min)<\/strong><\/td>\n<td width=\"142\"><strong>Quantity (%m\/m)<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"106\">FAME<\/td>\n<td width=\"112\">103139<\/td>\n<td width=\"142\">96,6<\/td>\n<\/tr>\n<tr>\n<td width=\"106\">Linolenic Acid<\/td>\n<td width=\"112\">7599,2<\/td>\n<td width=\"142\">7,1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"color: #1b66b1;\">Table 3.<\/span> Analytical results Biodiesel Assay<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"106\"><strong>\u00a0<\/strong><\/td>\n<td width=\"130\"><strong>Quantity (%m\/m)<\/strong><\/td>\n<td width=\"132\"><strong>Quantity (%m\/m)<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"106\">Average<\/td>\n<td width=\"130\">96,4<\/td>\n<td width=\"132\">7,1<\/td>\n<\/tr>\n<tr>\n<td width=\"106\">Standard Deviation<\/td>\n<td width=\"130\">0,20<\/td>\n<td width=\"132\">0,015<\/td>\n<\/tr>\n<tr>\n<td width=\"106\">RSD (%)<\/td>\n<td width=\"130\">0,21<\/td>\n<td width=\"132\">0,21<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"color: #1b66b1;\">Table 4.<\/span> Repeatability Results<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" loading=\"lazy\" class=\"alignnone wp-image-34104\" src=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/Fig-2-747x534-1.jpg\" alt=\"EN 14103\" width=\"455\" height=\"325\" srcset=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/Fig-2-747x534-1.jpg 747w, https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/Fig-2-747x534-1-300x214.jpg 300w\" sizes=\"auto, (max-width: 455px) 100vw, 455px\" \/><br \/>\n<span style=\"color: #1b66b1;\">Fig. 2<\/span> Repeatability figures. Red lines indicate the maximum and minimum allowed variation limits specified in the method.<\/p>\n<h2>Conclusion<\/h2>\n<p>This application note demonstrates the suitability of SCION Instruments Analyser for EN 14103, for the analysis of biodiesel. The repeatability data demonstrates good system integrity. The biodiesel sample tested in this application note fulfilled the requirements stated in EN 14214 Therefore, the system is well suited to the analysis of total FAME and Linolenic Acid Methyl Esters in Biodiesel According to EN 14103.<\/p>\n<h2>Download the Application Note<\/h2>\n<p>You can download the complete application note as a pdf: <a href=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2024\/02\/AN076v2-Determination-of-Total-FAME-and-Linolenic-Acid-Methyl-Esters-in-Biodiesel-According-to-EN14103.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Determination of Total FAME and Linolenic Acid Methyl Esters in Biodiesel<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Introduction For biodiesel to be used as a motor fuel or blended with petroleum diesel, it must conform to standard specifications (ASTM D 6751 or EN-14214). There are standard GC methods in use today to determine if biodiesel conforms to the standard specifications, one of which is EN-14103, used to determine the ester and linoleic [&hellip;]<\/p>\n","protected":false},"author":15,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-35401","page","type-page","status-publish","hentry"],"acf":{"rf_hero_height":"default","rf_hero_type":"default","rf_hero_vertpos":"50","rf_hero_horizpos":"50","rf_hero_title":"","rf_hero_textcol":"light","rf_hero_bgcol":"white","rf_hero_tint":false,"rf_hero_title_hide":false,"rf_further_reading_posts":false},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.0 (Yoast SEO v27.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Determination of Total FAME and Linolenic Acid Methyl Esters in Biodiesel<\/title>\n<meta name=\"description\" content=\"Applicaition Note: Determination of Total FAME and Linolenic Acid Methyl Esters in Biodiesel. This paper describes work conducted on a gas chromatograph.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/scioninstruments.com\/us\/determination-of-total-fame-and-linolenic-acid-methyl-esters-in-biodiesel\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Determination of Total FAME and Linolenic Acid Methyl Esters in Biodiesel\" \/>\n<meta property=\"og:description\" content=\"Applicaition Note: Determination of Total FAME and Linolenic Acid Methyl Esters in Biodiesel. This paper describes work conducted on a gas chromatograph.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/scioninstruments.com\/determination-of-total-fame-and-linolenic-acid-methyl-esters-in-biodiesel\/\" \/>\n<meta property=\"og:site_name\" content=\"SCION Instruments\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/scioninst\/\" \/>\n<meta property=\"article:modified_time\" content=\"2024-02-08T14:54:45+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/Untitled-design-6-600x600-1.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/scioninstruments.com\/us\/determination-of-total-fame-and-linolenic-acid-methyl-esters-in-biodiesel\/\",\"url\":\"https:\/\/scioninstruments.com\/determination-of-total-fame-and-linolenic-acid-methyl-esters-in-biodiesel\/\",\"name\":\"Determination of Total FAME and Linolenic Acid Methyl Esters in Biodiesel\",\"isPartOf\":{\"@id\":\"https:\/\/scioninstruments.com\/us\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/scioninstruments.com\/determination-of-total-fame-and-linolenic-acid-methyl-esters-in-biodiesel\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/scioninstruments.com\/determination-of-total-fame-and-linolenic-acid-methyl-esters-in-biodiesel\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/Untitled-design-6-600x600-1.png\",\"datePublished\":\"2020-12-11T11:37:08+00:00\",\"dateModified\":\"2024-02-08T14:54:45+00:00\",\"description\":\"Applicaition Note: Determination of Total FAME and Linolenic Acid Methyl Esters in Biodiesel. This paper describes work conducted on a gas chromatograph.\",\"breadcrumb\":{\"@id\":\"https:\/\/scioninstruments.com\/determination-of-total-fame-and-linolenic-acid-methyl-esters-in-biodiesel\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/scioninstruments.com\/determination-of-total-fame-and-linolenic-acid-methyl-esters-in-biodiesel\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/scioninstruments.com\/determination-of-total-fame-and-linolenic-acid-methyl-esters-in-biodiesel\/#primaryimage\",\"url\":\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/Untitled-design-6-600x600-1.png\",\"contentUrl\":\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/Untitled-design-6-600x600-1.png\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/scioninstruments.com\/determination-of-total-fame-and-linolenic-acid-methyl-esters-in-biodiesel\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/scioninstruments.com\/us\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Determination of Total FAME and Linolenic Acid Methyl Esters in Biodiesel\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/scioninstruments.com\/us\/#website\",\"url\":\"https:\/\/scioninstruments.com\/us\/\",\"name\":\"SCION Instruments\",\"description\":\"Gas and Liquid Chromatography Solutions\",\"publisher\":{\"@id\":\"https:\/\/scioninstruments.com\/us\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/scioninstruments.com\/us\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/scioninstruments.com\/us\/#organization\",\"name\":\"SCION Instruments\",\"url\":\"https:\/\/scioninstruments.com\/us\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/scioninstruments.com\/us\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2025\/02\/SCION-logo-TC-Strap-CMYK-transparent-background-1.png\",\"contentUrl\":\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2025\/02\/SCION-logo-TC-Strap-CMYK-transparent-background-1.png\",\"width\":3000,\"height\":1500,\"caption\":\"SCION Instruments\"},\"image\":{\"@id\":\"https:\/\/scioninstruments.com\/us\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/scioninst\/\",\"https:\/\/www.linkedin.com\/company\/scion-instruments\/\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Determination of Total FAME and Linolenic Acid Methyl Esters in Biodiesel","description":"Applicaition Note: Determination of Total FAME and Linolenic Acid Methyl Esters in Biodiesel. This paper describes work conducted on a gas chromatograph.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/scioninstruments.com\/us\/determination-of-total-fame-and-linolenic-acid-methyl-esters-in-biodiesel\/","og_locale":"en_US","og_type":"article","og_title":"Determination of Total FAME and Linolenic Acid Methyl Esters in Biodiesel","og_description":"Applicaition Note: Determination of Total FAME and Linolenic Acid Methyl Esters in Biodiesel. This paper describes work conducted on a gas chromatograph.","og_url":"https:\/\/scioninstruments.com\/determination-of-total-fame-and-linolenic-acid-methyl-esters-in-biodiesel\/","og_site_name":"SCION Instruments","article_publisher":"https:\/\/www.facebook.com\/scioninst\/","article_modified_time":"2024-02-08T14:54:45+00:00","og_image":[{"url":"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/Untitled-design-6-600x600-1.png","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/scioninstruments.com\/us\/determination-of-total-fame-and-linolenic-acid-methyl-esters-in-biodiesel\/","url":"https:\/\/scioninstruments.com\/determination-of-total-fame-and-linolenic-acid-methyl-esters-in-biodiesel\/","name":"Determination of Total FAME and Linolenic Acid Methyl Esters in Biodiesel","isPartOf":{"@id":"https:\/\/scioninstruments.com\/us\/#website"},"primaryImageOfPage":{"@id":"https:\/\/scioninstruments.com\/determination-of-total-fame-and-linolenic-acid-methyl-esters-in-biodiesel\/#primaryimage"},"image":{"@id":"https:\/\/scioninstruments.com\/determination-of-total-fame-and-linolenic-acid-methyl-esters-in-biodiesel\/#primaryimage"},"thumbnailUrl":"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/Untitled-design-6-600x600-1.png","datePublished":"2020-12-11T11:37:08+00:00","dateModified":"2024-02-08T14:54:45+00:00","description":"Applicaition Note: Determination of Total FAME and Linolenic Acid Methyl Esters in Biodiesel. This paper describes work conducted on a gas chromatograph.","breadcrumb":{"@id":"https:\/\/scioninstruments.com\/determination-of-total-fame-and-linolenic-acid-methyl-esters-in-biodiesel\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/scioninstruments.com\/determination-of-total-fame-and-linolenic-acid-methyl-esters-in-biodiesel\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/scioninstruments.com\/determination-of-total-fame-and-linolenic-acid-methyl-esters-in-biodiesel\/#primaryimage","url":"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/Untitled-design-6-600x600-1.png","contentUrl":"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/Untitled-design-6-600x600-1.png"},{"@type":"BreadcrumbList","@id":"https:\/\/scioninstruments.com\/determination-of-total-fame-and-linolenic-acid-methyl-esters-in-biodiesel\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/scioninstruments.com\/us\/"},{"@type":"ListItem","position":2,"name":"Determination of Total FAME and Linolenic Acid Methyl Esters in Biodiesel"}]},{"@type":"WebSite","@id":"https:\/\/scioninstruments.com\/us\/#website","url":"https:\/\/scioninstruments.com\/us\/","name":"SCION Instruments","description":"Gas and Liquid Chromatography Solutions","publisher":{"@id":"https:\/\/scioninstruments.com\/us\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/scioninstruments.com\/us\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/scioninstruments.com\/us\/#organization","name":"SCION Instruments","url":"https:\/\/scioninstruments.com\/us\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/scioninstruments.com\/us\/#\/schema\/logo\/image\/","url":"https:\/\/scioninstruments.com\/wp-content\/uploads\/2025\/02\/SCION-logo-TC-Strap-CMYK-transparent-background-1.png","contentUrl":"https:\/\/scioninstruments.com\/wp-content\/uploads\/2025\/02\/SCION-logo-TC-Strap-CMYK-transparent-background-1.png","width":3000,"height":1500,"caption":"SCION Instruments"},"image":{"@id":"https:\/\/scioninstruments.com\/us\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/scioninst\/","https:\/\/www.linkedin.com\/company\/scion-instruments\/"]}]}},"_links":{"self":[{"href":"https:\/\/scioninstruments.com\/us\/wp-json\/wp\/v2\/pages\/35401","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scioninstruments.com\/us\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/scioninstruments.com\/us\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/scioninstruments.com\/us\/wp-json\/wp\/v2\/users\/15"}],"replies":[{"embeddable":true,"href":"https:\/\/scioninstruments.com\/us\/wp-json\/wp\/v2\/comments?post=35401"}],"version-history":[{"count":0,"href":"https:\/\/scioninstruments.com\/us\/wp-json\/wp\/v2\/pages\/35401\/revisions"}],"wp:attachment":[{"href":"https:\/\/scioninstruments.com\/us\/wp-json\/wp\/v2\/media?parent=35401"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}