{"id":34612,"date":"2020-12-02T16:10:41","date_gmt":"2020-12-02T16:10:41","guid":{"rendered":"https:\/\/scioninstruments.com\/analysis-of-permanent-gases-in-c2-and-c3-hydrocarbon-products-by-gas-chromatography-and-pulsed-discharge-helium-ionization-detection\/"},"modified":"2023-10-23T17:12:17","modified_gmt":"2023-10-23T16:12:17","slug":"analysis-of-permanent-gases-in-c2-and-c3-hydrocarbon-products-by-gas-chromatography-and-pulsed-discharge-helium-ionization-detection","status":"publish","type":"page","link":"https:\/\/scioninstruments.com\/us\/analysis-of-permanent-gases-in-c2-and-c3-hydrocarbon-products-by-gas-chromatography-and-pulsed-discharge-helium-ionization-detection\/","title":{"rendered":"Analysis of permanent gases in C2 and C3 Hydrocarbon Products by Gas Chromatography and Pulsed Discharge Helium Ionization Detection"},"content":{"rendered":"<h2>Introduction<img loading=\"lazy\" decoding=\"async\" loading=\"lazy\" class=\"alignright\" src=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/11\/Untitled-design-29-300x300.png\" alt=\"ASTM D8098\" width=\"250\" height=\"250\" \/><\/h2>\n<p>The production of polymers requires a high grade of ethylene and propylene building blocks. To determine the purity of polymer grade ethylene and propylene Scion Instruments has developed a configuration that determines the trace impurities of permanent gases in C2 and C3 matrices. This configuration will provide results according to ASTM D8098. This test method covers the determination of hydrogen, oxygen, nitrogen, methane, carbon monoxide, and carbon dioxide in the parts per billion mole (nmol\/mol) to parts per million mole (\u03bcmol\/mol) range in C2 and C3 hydrocarbons.<\/p>\n<p>The instrument configuration consists of 2 channels. The first channel consists of a non O2 adsorbing pre-column and a molecular sieve column. The pre-column allows the complete elution of hydrogen, oxygen, nitrogen, methane and carbon monoxide onto the analytical column. All components heavier than these components (including CO2 and heavier) are backflushed to vent. The second channel consists of 2 porous polymer columns which separate a composite \u201cair\u201d peak (H2\/O2\/N2\/ CO) from methane and CO2. All components heavier than CO2 are backflushed to vent. Column dimensions are optimized for the combination of both channels onto one PDHID (PDD) detector. Sample introduction is performed by the Scion Instruments integrated Gasifier. This device is capable of handling LPG samples of C2 through C4, effectively reducing the pressure resulting from gasifying the liquefied sample. GC control and data handling was performed using Scion Instruments Compass CDS\u2122.<\/p>\n<h2>System Overview<\/h2>\n<h2><a href=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/Picture1-3.png\"><img loading=\"lazy\" decoding=\"async\" loading=\"lazy\" class=\"alignnone wp-image-34389\" src=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/Picture1-3.png\" alt=\"System overview - Permanent Gases\" width=\"637\" height=\"350\" srcset=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/Picture1-3.png 637w, https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/Picture1-3-300x165.png 300w\" sizes=\"auto, (max-width: 637px) 100vw, 637px\" \/><\/a><\/h2>\n<h2><\/h2>\n<h2>Instrumental Settings<\/h2>\n<table width=\"321\">\n<tbody>\n<tr>\n<td width=\"160\"><strong>Integrated Gasifier<\/strong><\/td>\n<td width=\"160\">120\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"160\"><strong>Valve Oven<\/strong><\/td>\n<td width=\"160\">50\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"160\"><strong>GC Oven<\/strong><\/td>\n<td width=\"160\">80\u00b0C isothermal<\/p>\n<p>for 18.50 minutes<\/td>\n<\/tr>\n<tr>\n<td width=\"160\"><strong>Column Flows<\/strong><\/td>\n<td width=\"160\">15ml\/min<\/p>\n<p>UHP Helium<\/td>\n<\/tr>\n<tr>\n<td width=\"160\"><strong>Detector PDHID<\/strong><\/td>\n<td width=\"160\">120\u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><\/h2>\n<h2>Chromatography<\/h2>\n<h2><a href=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/Picture2-1.png\"><img loading=\"lazy\" decoding=\"async\" loading=\"lazy\" class=\"alignnone wp-image-34395 size-full\" src=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/Picture2-1.png\" alt=\"permanent gases in Helium\" width=\"869\" height=\"502\" srcset=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/Picture2-1.png 869w, https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/Picture2-1-300x173.png 300w, https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/Picture2-1-768x444.png 768w\" sizes=\"auto, (max-width: 869px) 100vw, 869px\" \/><\/a> <a href=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/Picture3-1.png\"><img loading=\"lazy\" decoding=\"async\" loading=\"lazy\" class=\"alignnone wp-image-34401 size-full\" src=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/Picture3-1.png\" alt=\"ethylene sample\" width=\"869\" height=\"500\" srcset=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/Picture3-1.png 869w, https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/Picture3-1-300x173.png 300w, https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/Picture3-1-768x442.png 768w\" sizes=\"auto, (max-width: 869px) 100vw, 869px\" \/><\/a><\/h2>\n<h2>Area Repeatability (n=20) 2 ppm permanent gas test mix<\/h2>\n<table style=\"height: 175px;\" width=\"658\">\n<tbody>\n<tr>\n<td width=\"70\"><\/td>\n<td width=\"70\"><strong>Air<\/strong><\/td>\n<td width=\"70\"><strong>CH4<\/strong><\/td>\n<td width=\"70\"><strong>CO2<\/strong><\/td>\n<td width=\"70\"><strong>H2<\/strong><\/td>\n<td width=\"70\"><strong>O2<\/strong><\/td>\n<td width=\"70\"><strong>N2<\/strong><\/td>\n<td width=\"70\"><strong>CH4<\/strong><\/td>\n<td width=\"70\"><strong>CO<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"70\"><strong>Mean<\/strong><\/td>\n<td width=\"70\">5008965<\/td>\n<td width=\"70\">3393477<\/td>\n<td width=\"70\">2652170<\/td>\n<td width=\"70\">482111<\/td>\n<td width=\"70\">1911297<\/td>\n<td width=\"70\">2242025<\/td>\n<td width=\"70\">3731809<\/td>\n<td width=\"70\">1781911<\/td>\n<\/tr>\n<tr>\n<td width=\"70\"><strong>Std Dev<\/strong><\/td>\n<td width=\"70\">2688.4<\/td>\n<td width=\"70\">12845<\/td>\n<td width=\"70\">9044<\/td>\n<td width=\"70\">1530<\/td>\n<td width=\"70\">2020<\/td>\n<td width=\"70\">6512<\/td>\n<td width=\"70\">12683<\/td>\n<td width=\"70\">6580<\/td>\n<\/tr>\n<tr>\n<td width=\"70\"><strong>Rsd %<\/strong><\/td>\n<td width=\"70\">0.05<\/td>\n<td width=\"70\">0.38<\/td>\n<td width=\"70\">0.34<\/td>\n<td width=\"70\">0.32<\/td>\n<td width=\"70\">0.11<\/td>\n<td width=\"70\">0.29<\/td>\n<td width=\"70\">0.34<\/td>\n<td width=\"70\">0.37<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Method Detection Limit LOD-LOQ calculation<\/h2>\n<table style=\"height: 345px;\" width=\"659\">\n<tbody>\n<tr>\n<td width=\"71\"><\/td>\n<td width=\"71\"><strong>Air<\/strong><\/td>\n<td width=\"74\"><strong>CH4<\/strong><\/td>\n<td width=\"77\"><strong>CO2<\/strong><\/td>\n<td width=\"71\"><strong>H2<\/strong><\/td>\n<td width=\"68\"><strong>O2<\/strong><\/td>\n<td width=\"71\"><strong>N2<\/strong><\/td>\n<td width=\"70\"><strong>CH4<\/strong><\/td>\n<td width=\"68\"><strong>CO<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"71\"><strong>Mean<\/strong><\/td>\n<td width=\"71\">5008965<\/td>\n<td width=\"74\">3393477<\/td>\n<td width=\"77\">2652170<\/td>\n<td width=\"71\">482111<\/td>\n<td width=\"68\">1911297<\/td>\n<td width=\"71\">2242025<\/td>\n<td width=\"70\">3731809<\/td>\n<td width=\"68\">1781911<\/td>\n<\/tr>\n<tr>\n<td width=\"71\"><strong>Std Dev<\/strong><\/td>\n<td width=\"71\">2688<\/td>\n<td width=\"74\">12845<\/td>\n<td width=\"77\">9044<\/td>\n<td width=\"71\">1530<\/td>\n<td width=\"68\">2020<\/td>\n<td width=\"71\">6512<\/td>\n<td width=\"70\">12683<\/td>\n<td width=\"68\">6580<\/td>\n<\/tr>\n<tr>\n<td width=\"71\"><strong>Rsd %<\/strong><\/td>\n<td width=\"71\">0.05<\/td>\n<td width=\"74\">0.38<\/td>\n<td width=\"77\">0.34<\/td>\n<td width=\"71\">0.32<\/td>\n<td width=\"68\">0.11<\/td>\n<td width=\"71\">0.29<\/td>\n<td width=\"70\">0.34<\/td>\n<td width=\"68\">0.37<\/td>\n<\/tr>\n<tr>\n<td width=\"71\"><strong>Amount test mix<\/strong><\/td>\n<td width=\"71\">PPM<\/td>\n<td width=\"74\">2<\/td>\n<td width=\"77\">2<\/td>\n<td width=\"71\">2<\/td>\n<td width=\"68\">2<\/td>\n<td width=\"71\">2<\/td>\n<td width=\"70\">2<\/td>\n<td width=\"68\">2<\/td>\n<\/tr>\n<tr>\n<td width=\"71\"><strong>LOD<\/strong><\/td>\n<td width=\"71\">PPB<\/td>\n<td width=\"74\">20<\/td>\n<td width=\"77\">20<\/td>\n<td width=\"71\">17<\/td>\n<td width=\"68\">6<\/td>\n<td width=\"71\">16<\/td>\n<td width=\"70\">19<\/td>\n<td width=\"68\">20<\/td>\n<\/tr>\n<tr>\n<td width=\"71\"><strong>LOQ<\/strong><\/td>\n<td width=\"71\">PPB<\/td>\n<td width=\"74\">68<\/td>\n<td width=\"77\">61<\/td>\n<td width=\"71\">58<\/td>\n<td width=\"68\">19<\/td>\n<td width=\"71\">52<\/td>\n<td width=\"70\">61<\/td>\n<td width=\"68\">67<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Conclusion<\/h2>\n<p>As the results clearly show, this system is perfectly suited for the analysis of trace impurities in ethylene matrices. Detection limits are at ppb level, depending on the type of component. Due to the use of a gasifier and the backflush configuration, matrices of C3 and C4 could also be analyzed without difficulty.<\/p>\n<p>The Scion Instruments D8098 configuration is perfectly suitable for the determination of permanent gas impurities in ethylene and propylene matrices at ppb levels. The use of robust industry standard inert materials, coupled with purged MS leak specification valves and inert preconditioned columns with welded ends ensures a robust instrument ideal for the olefin producing and the polymer industry.<\/p>\n<h2>Download Application Note<\/h2>\n<p>You can download the complete Application Note: <a href=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/12\/SCION-Application-Note-A0086-ASTM-D-8098.pdf\">Analysis of permanent gases in C2 and C3 Hydrocarbon Products by Gas Chromatography and Pulsed Discharge Helium Ionization Detection<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Introduction The production of polymers requires a high grade of ethylene and propylene building blocks. To determine the purity of polymer grade ethylene and propylene Scion Instruments has developed a configuration that determines the trace impurities of permanent gases in C2 and C3 matrices. This configuration will provide results according to ASTM D8098. This test [&hellip;]<\/p>\n","protected":false},"author":15,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-34612","page","type-page","status-publish","hentry"],"acf":{"rf_hero_height":"default","rf_hero_type":"default","rf_hero_vertpos":"50","rf_hero_horizpos":"50","rf_hero_title":"","rf_hero_textcol":"light","rf_hero_bgcol":"white","rf_hero_tint":false,"rf_hero_title_hide":false,"rf_further_reading_posts":false},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.0 (Yoast SEO v27.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Analysis of permanent gases in C2 and C3 Hydrocarbon Products by Gas Chromatography and Pulsed Discharge Helium Ionization Detection<\/title>\n<meta name=\"description\" content=\"This test method covers the determination of hydrogen, oxygen, nitrogen, methane, carbon monoxide, and carbon dioxide. Read more...\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/scioninstruments.com\/us\/analysis-of-permanent-gases-in-c2-and-c3-hydrocarbon-products-by-gas-chromatography-and-pulsed-discharge-helium-ionization-detection\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Analysis of permanent gases in C2 and C3 Hydrocarbon Products by Gas Chromatography and Pulsed Discharge Helium Ionization Detection\" \/>\n<meta property=\"og:description\" content=\"This test method covers the determination of hydrogen, oxygen, nitrogen, methane, carbon monoxide, and carbon dioxide. Read more...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/scioninstruments.com\/analysis-of-permanent-gases-in-c2-and-c3-hydrocarbon-products-by-gas-chromatography-and-pulsed-discharge-helium-ionization-detection\/\" \/>\n<meta property=\"og:site_name\" content=\"SCION Instruments\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/scioninst\/\" \/>\n<meta property=\"article:modified_time\" content=\"2023-10-23T16:12:17+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/11\/Untitled-design-29-300x300.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/scioninstruments.com\/us\/analysis-of-permanent-gases-in-c2-and-c3-hydrocarbon-products-by-gas-chromatography-and-pulsed-discharge-helium-ionization-detection\/\",\"url\":\"https:\/\/scioninstruments.com\/analysis-of-permanent-gases-in-c2-and-c3-hydrocarbon-products-by-gas-chromatography-and-pulsed-discharge-helium-ionization-detection\/\",\"name\":\"Analysis of permanent gases in C2 and C3 Hydrocarbon Products by Gas Chromatography and Pulsed Discharge Helium Ionization Detection\",\"isPartOf\":{\"@id\":\"https:\/\/scioninstruments.com\/us\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/scioninstruments.com\/analysis-of-permanent-gases-in-c2-and-c3-hydrocarbon-products-by-gas-chromatography-and-pulsed-discharge-helium-ionization-detection\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/scioninstruments.com\/analysis-of-permanent-gases-in-c2-and-c3-hydrocarbon-products-by-gas-chromatography-and-pulsed-discharge-helium-ionization-detection\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/11\/Untitled-design-29-300x300.png\",\"datePublished\":\"2020-12-02T16:10:41+00:00\",\"dateModified\":\"2023-10-23T16:12:17+00:00\",\"description\":\"This test method covers the determination of hydrogen, oxygen, nitrogen, methane, carbon monoxide, and carbon dioxide. Read more...\",\"breadcrumb\":{\"@id\":\"https:\/\/scioninstruments.com\/analysis-of-permanent-gases-in-c2-and-c3-hydrocarbon-products-by-gas-chromatography-and-pulsed-discharge-helium-ionization-detection\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/scioninstruments.com\/analysis-of-permanent-gases-in-c2-and-c3-hydrocarbon-products-by-gas-chromatography-and-pulsed-discharge-helium-ionization-detection\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/scioninstruments.com\/analysis-of-permanent-gases-in-c2-and-c3-hydrocarbon-products-by-gas-chromatography-and-pulsed-discharge-helium-ionization-detection\/#primaryimage\",\"url\":\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/11\/Untitled-design-29-300x300.png\",\"contentUrl\":\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/11\/Untitled-design-29-300x300.png\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/scioninstruments.com\/analysis-of-permanent-gases-in-c2-and-c3-hydrocarbon-products-by-gas-chromatography-and-pulsed-discharge-helium-ionization-detection\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/scioninstruments.com\/us\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Analysis of permanent gases in C2 and C3 Hydrocarbon Products by Gas Chromatography and Pulsed Discharge Helium Ionization Detection\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/scioninstruments.com\/us\/#website\",\"url\":\"https:\/\/scioninstruments.com\/us\/\",\"name\":\"SCION Instruments\",\"description\":\"Gas and Liquid Chromatography Solutions\",\"publisher\":{\"@id\":\"https:\/\/scioninstruments.com\/us\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/scioninstruments.com\/us\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/scioninstruments.com\/us\/#organization\",\"name\":\"SCION Instruments\",\"url\":\"https:\/\/scioninstruments.com\/us\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/scioninstruments.com\/us\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2025\/02\/SCION-logo-TC-Strap-CMYK-transparent-background-1.png\",\"contentUrl\":\"https:\/\/scioninstruments.com\/wp-content\/uploads\/2025\/02\/SCION-logo-TC-Strap-CMYK-transparent-background-1.png\",\"width\":3000,\"height\":1500,\"caption\":\"SCION Instruments\"},\"image\":{\"@id\":\"https:\/\/scioninstruments.com\/us\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/scioninst\/\",\"https:\/\/www.linkedin.com\/company\/scion-instruments\/\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Analysis of permanent gases in C2 and C3 Hydrocarbon Products by Gas Chromatography and Pulsed Discharge Helium Ionization Detection","description":"This test method covers the determination of hydrogen, oxygen, nitrogen, methane, carbon monoxide, and carbon dioxide. Read more...","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/scioninstruments.com\/us\/analysis-of-permanent-gases-in-c2-and-c3-hydrocarbon-products-by-gas-chromatography-and-pulsed-discharge-helium-ionization-detection\/","og_locale":"en_US","og_type":"article","og_title":"Analysis of permanent gases in C2 and C3 Hydrocarbon Products by Gas Chromatography and Pulsed Discharge Helium Ionization Detection","og_description":"This test method covers the determination of hydrogen, oxygen, nitrogen, methane, carbon monoxide, and carbon dioxide. Read more...","og_url":"https:\/\/scioninstruments.com\/analysis-of-permanent-gases-in-c2-and-c3-hydrocarbon-products-by-gas-chromatography-and-pulsed-discharge-helium-ionization-detection\/","og_site_name":"SCION Instruments","article_publisher":"https:\/\/www.facebook.com\/scioninst\/","article_modified_time":"2023-10-23T16:12:17+00:00","og_image":[{"url":"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/11\/Untitled-design-29-300x300.png","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/scioninstruments.com\/us\/analysis-of-permanent-gases-in-c2-and-c3-hydrocarbon-products-by-gas-chromatography-and-pulsed-discharge-helium-ionization-detection\/","url":"https:\/\/scioninstruments.com\/analysis-of-permanent-gases-in-c2-and-c3-hydrocarbon-products-by-gas-chromatography-and-pulsed-discharge-helium-ionization-detection\/","name":"Analysis of permanent gases in C2 and C3 Hydrocarbon Products by Gas Chromatography and Pulsed Discharge Helium Ionization Detection","isPartOf":{"@id":"https:\/\/scioninstruments.com\/us\/#website"},"primaryImageOfPage":{"@id":"https:\/\/scioninstruments.com\/analysis-of-permanent-gases-in-c2-and-c3-hydrocarbon-products-by-gas-chromatography-and-pulsed-discharge-helium-ionization-detection\/#primaryimage"},"image":{"@id":"https:\/\/scioninstruments.com\/analysis-of-permanent-gases-in-c2-and-c3-hydrocarbon-products-by-gas-chromatography-and-pulsed-discharge-helium-ionization-detection\/#primaryimage"},"thumbnailUrl":"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/11\/Untitled-design-29-300x300.png","datePublished":"2020-12-02T16:10:41+00:00","dateModified":"2023-10-23T16:12:17+00:00","description":"This test method covers the determination of hydrogen, oxygen, nitrogen, methane, carbon monoxide, and carbon dioxide. Read more...","breadcrumb":{"@id":"https:\/\/scioninstruments.com\/analysis-of-permanent-gases-in-c2-and-c3-hydrocarbon-products-by-gas-chromatography-and-pulsed-discharge-helium-ionization-detection\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/scioninstruments.com\/analysis-of-permanent-gases-in-c2-and-c3-hydrocarbon-products-by-gas-chromatography-and-pulsed-discharge-helium-ionization-detection\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/scioninstruments.com\/analysis-of-permanent-gases-in-c2-and-c3-hydrocarbon-products-by-gas-chromatography-and-pulsed-discharge-helium-ionization-detection\/#primaryimage","url":"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/11\/Untitled-design-29-300x300.png","contentUrl":"https:\/\/scioninstruments.com\/wp-content\/uploads\/2020\/11\/Untitled-design-29-300x300.png"},{"@type":"BreadcrumbList","@id":"https:\/\/scioninstruments.com\/analysis-of-permanent-gases-in-c2-and-c3-hydrocarbon-products-by-gas-chromatography-and-pulsed-discharge-helium-ionization-detection\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/scioninstruments.com\/us\/"},{"@type":"ListItem","position":2,"name":"Analysis of permanent gases in C2 and C3 Hydrocarbon Products by Gas Chromatography and Pulsed Discharge Helium Ionization Detection"}]},{"@type":"WebSite","@id":"https:\/\/scioninstruments.com\/us\/#website","url":"https:\/\/scioninstruments.com\/us\/","name":"SCION Instruments","description":"Gas and Liquid Chromatography Solutions","publisher":{"@id":"https:\/\/scioninstruments.com\/us\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/scioninstruments.com\/us\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/scioninstruments.com\/us\/#organization","name":"SCION Instruments","url":"https:\/\/scioninstruments.com\/us\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/scioninstruments.com\/us\/#\/schema\/logo\/image\/","url":"https:\/\/scioninstruments.com\/wp-content\/uploads\/2025\/02\/SCION-logo-TC-Strap-CMYK-transparent-background-1.png","contentUrl":"https:\/\/scioninstruments.com\/wp-content\/uploads\/2025\/02\/SCION-logo-TC-Strap-CMYK-transparent-background-1.png","width":3000,"height":1500,"caption":"SCION Instruments"},"image":{"@id":"https:\/\/scioninstruments.com\/us\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/scioninst\/","https:\/\/www.linkedin.com\/company\/scion-instruments\/"]}]}},"_links":{"self":[{"href":"https:\/\/scioninstruments.com\/us\/wp-json\/wp\/v2\/pages\/34612","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scioninstruments.com\/us\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/scioninstruments.com\/us\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/scioninstruments.com\/us\/wp-json\/wp\/v2\/users\/15"}],"replies":[{"embeddable":true,"href":"https:\/\/scioninstruments.com\/us\/wp-json\/wp\/v2\/comments?post=34612"}],"version-history":[{"count":0,"href":"https:\/\/scioninstruments.com\/us\/wp-json\/wp\/v2\/pages\/34612\/revisions"}],"wp:attachment":[{"href":"https:\/\/scioninstruments.com\/us\/wp-json\/wp\/v2\/media?parent=34612"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}